All Categories
Benchtop Centrifuge

Benchtop Centrifuge

Ụlọ> ngwaahịa > Centrifuges > Benchtop Centrifuge

Benchtop Centrifuge Ọsọ Ọsọ Na-enweghị Mkpọchi Nchekwa moto

ngwa: Ụlọ ọgwụ, ụlọ ọgwụ anụmanụ, ụlọ nyocha nri, mahadum & kọleji, ụlọ nyocha ọgwụ, ụlọ ọrụ omenala cell, ọdụ ụmụaka
Max. Kwuru ọsọ 4000 rpm
Oke.RCF 2268gg
Max ikike 6 * 50ml rotor akụkụ akụkụ
Rotors dakọtara Rotors akụkụ a kapịrị ọnụ
Display LCD
Model Number: KC40-T
asambodo: CE, ISO13485, ISO9001, SFDA
Akwụkwọ ikike Akwụkwọ ikike afọ 1 maka igwe dum, akwụkwọ ikike afọ 3 maka compressor na akwụkwọ ikike afọ 5 maka moto. Akụkụ ngbanwe efu na mbupu n'ime akwụkwọ ikike.
  • Description
  • Video
  • Nka na ụzụ nkọwa
  • Rotors na Ngwa
  • asọmpi Advantage

A na-enweta centrifuge benchtop KC40-T nwere ọtụtụ rotors nwere akụkụ kwụ ọtọ. Ngwa dị iche iche nwere ike ịnabata tubes site na 2 ml ruo 50 ml. RCF kachasị nke karịrị 2,680 x g dabara adaba maka ọtụtụ ebe a na-eji ya na nchọpụta ahụike, ọgwụ anụmanụ, ọgwụ, nyocha gburugburu ebe obibi na mmepụta ụlọ ọrụ mmepụta ihe, yana mahadum na ebe nyocha.

Design

● Ụlọ ígwè, mkpuchi ígwè, na 304# igwe anaghị agba nchara centrifuge ụlọ bụ autoclave-nwere ike na-eguzogide ọgwụ na mmiri mmiri disinfection.

● Aluminom alloy rotor.

● Mpempe ihe nlele na mkpuchi maka nhazi ọsọ ọsọ na nha mkpọtụ.

● Njikwa microprocessor nwere moto DC na-enweghị brushes nke na-adịghị arụ ọrụ.

● LCD gosipụtara parampat nke Speed, Timer, RCF.

1

Dị mfe ojiji

● Mkpuchi mkpuchi akpaaka na ijide n'oge rotor na-agba ọsọ.

● rotors na-agbanwe ngwa ngwa.

● Nchọpụta nsogbu akpaaka na-egosi koodu njehie na mkpu na ihuenyo.

● Teknụzụ patent “Ogbi.” Ọkwa mkpọtụ dị ala karịa decibel 55 n'ọsọ ntụgharị kachasị elu.

Centrifuge Clinical T4-L dị ala

Safety

● Emepụtara dịka iwu nchekwa mba ụwa siri dị (dịka IEC 61010)

● Nchekwa mkpuchi mkpuchi eletrik, ọnụ ụzọ enweghị ike imeghe mgbe rotor na-agba ọsọ na igwe agaghị agba ọsọ mgbe mkpuchi meghere na koodu njehie pụtara.

● Mwepu mkpuchi mkpuchi mberede mgbe ike dara.

● Mkpịsị ọkụ gas maka nchekwa mkpuchi mkpuchi.

● A na-eme ihe nchekwa nchekwa maka oke ọsọ ọsọ, enweghị aha na nchọpụta nsogbu ụgbọala wdg iji hụ na nchekwa igwe mmadụ.

Centrifuge Clinical T4-L dị ala

Oke ọsọ (rpm) 0-4000rpm nwere ike idozi Izi ezi ọsọ 10rpm
Oke ike(ml) 12 * 20ml Oke RCF (xg) 0-2680xg mgbanwe
Noise (dBA) ≦55dB(A) Oge oge 0-99 nkeji mgbanwe
Dimension (mm) 430x320x250mm Net arọ (na-enweghị rotor) 18KGS
ike ọkọnọ AC220V, 50HZ, 5A, 120W
Ee e Rotor ikike Max. Kwuru Oke.RCF Note
NO.11683337299238923 rotor akụkụ 24 × 10 / 5ml 4000r / min 2680gg PP / PC tube / Vacuum ọbara mkpokọta tubes
nkwụnye 24 × 2ml
nkwụnye 24 × 1.5ml
NO.21683337299382301 rotor akụkụ 6 × 50 ml 4000r / min 2680gg PP / PC tube
nkwụnye 6 × 15 / 10ml
nkwụnye 6 × 5 / 2ml
Enweghi aha-4

1. Onye na-emepụta centrifuge ọkachamara, ọnụahịa asọmpi.

2. ISO9001, ISO13485, CE, SFDA Asambodo, igwe niile na-enweta ule siri ike na nkwakọ ngwaahịa dị mma tupu ụgbọ njem.

3. Ogologo oge oru nkwado na ọkachamara ahịa ọrụ na ọ bụla ogbo nke ngwaahịa ahịa, nnyefe na operation.Our ukwuu ruru eru na ahụmahụ ọrụ otu na-enye gị na a pụrụ iche larịị nke nkwado gị zuo n'ihi na ọ bụ dum ndụ.

4. Anyị nwekwara ike na-enye ngwọta ahaziri maka ndị ahịa 'chọrọ pụrụ iche.

5. Kwadoro ya na otu ndị injinia na-arụ ọrụ nke ọma na-akwado site na afọ nke ahụmahụ na mpaghara ha, ụlọ ọrụ ahụ na-ahụ na ngwaahịa ọ bụla nke na-ahapụ ụlọ ọrụ mmepụta ihe ruru akara n'akụkụ niile.

NCHỌPỤTA
0
Nkata nyocha
    Ajuju ase gi bu ihe efu
Efuase