ỌH HR H HOT
Benchtop Micro Centrifuges Refrigerated nke obere ikike maka ụlọ akụ ọbara
| ngwa: | Ụgbọ mmiri na-anakọta ọbara, ụlọ na-anakọta ọbara |
| Max. Kwuru ọsọ | 6000 rpm |
| Oke.RCF | 4860gg |
| Max ikike | 4 * 100ml rotor ịwụ ịwụ |
| Rotors dakọtara | Rotors akụkụ a kapịrị ọnụ + Na-atụgharị rotor |
| Display | LCD, metụ ihuenyo ihuenyo agba inch ise |
| Model Number: | KCL-60R |
| asambodo: | CE, ISO13485, ISO9001, SFDA |
| Akwụkwọ ikike | Akwụkwọ ikike afọ 1 maka igwe dum, akwụkwọ ikike afọ 3 maka compressor na akwụkwọ ikike afọ 5 maka moto. Akụkụ ngbanwe efu na mbupu n'ime akwụkwọ ikike. |
- Description
- Video
- Nka na ụzụ nkọwa
- Rotors na Ngwa
- asọmpi Advantage
Ndị ọrụ dị iche iche nwere ike iji trolleys na-anakọta ọbara ma ọ bụ ụlọ, yabụ microcentrifuge KCL-60R emebere maka ebumnuche a na-adịkarị ngwa ngwa ma rụọ ọrụ nke ọma, yana nnukwu ịgba ọsọ na oge okirikiri dị mkpụmkpụ, dị mfe iji na nghọta. O nwere ntọala emebere ya nke na-eme ka ọ dị mfe ịgbatị ọbara nke ọma. Ọ na-edozi ọbara ngwa ngwa iji hụ na ọ ga-adịgide maka ọgwụgwọ. Ejiri 4 x 100ml rotor kwụ ọtọ, nhọrọ nucleic acid centrifuge tubes, oghere ọbara mkpokọta tubes, 15ml, 10ml, 8ml, 5ml, 2ml na ndị ọzọ centrifuge tube nkwụnye.
Design
● Ụlọ ígwè, mkpuchi ígwè, na igwe anaghị agba nchara centrifuge ụlọ bụ autoclave nwere ike na-eguzogide ọgwụ na mmiri mmiri na-efe efe.
● Mpempe ihe nlele na mkpuchi maka nhazi ọsọ ọsọ na nha mkpọtụ.
● Microprocessor njikwa na ugboro mgbanwe AC moto mbanye.
● Nabata sistemụ refrigeration nchekwa gburugburu ebe obibi dị elu, enweghị mmetọ gburugburu ebe obibi, njikwa okpomọkụ dị elu.
● LCD t
● LCD ihuenyo mmetụ na mfe & doro anya interface, gosi niile parameters nke ngwá ọrụ, onye ọrụ nwere ike ịtọ centrifugal ọsọ na centrifugal oge aka ike.
● Sistemu ọrụ Centrifuge nwere okwuntughe iji gbochie iji ya eme ihe, interface USB mpụga, nwere ike soro ma chọpụta data centrifugal karịrị 1000.
● Ìhè arọ, obere size, mfe, mara mma na-emesapụ aka ọdịdị, pụrụ iche suction cup ụkwụ nwere ike ike ịghọta na ọnyịnye n'elu, ọbụna mgbe ụgbọala na-enweghị nchegbu banyere centrifuge ije.
● Enwere ike gbanwee ụkwụ iko iko anọ dị elu ma dị ala, ebe centrifuge wuru na ọkwa, ụgbọ nchịkọta ọbara n'ihe banyere ala na-adịghị mma ka nwere ike ịhazigharị centrifuge na steeti kwụsiri ike, mmetụta centrifugal kacha mma, iji nchekwa dị mma. .
● Ejiri 4 x 100ml rotor kwụ ọtọ, nhọrọ nucleic acid centrifuge tubes, oghere ọbara mkpokọta tubes, 15ml, 10ml, 8ml, 5ml, 2ml na ndị ọzọ centrifuge tube nkwụnye.

Dị mfe ojiji
● Sistemụ refrigeration n'efu CFC, rotors precooling na-arụ ọrụ n'oge nọrọ na njikere, njikwa okpomọkụ ziri ezi ruo - 9°C.
● Enwere ike ịhazi ma chekwaa, na-echekwa ihe ruru mmemme 1000 ma na-enye ndị ọrụ ohere ịnweta otu igodo igodo ozugbo. Oke echekwara: ngwakọta na-anọgide na ebe nchekwa ọbụlagodi mgbe agbanyụrụ centrifugation.
● Mkpuchi mkpuchi akpaaka na ijide n'oge rotor na-agba ọsọ
● rotors na-agbanwe ngwa ngwa
● Nchọpụta nsogbu akpaaka na-egosi koodu njehie na mkpu na ihuenyo.
● Teknụzụ patent “Ogbi.” Site na asambodo “patent” mkpọtụ dị ala, mkpọtụ arụ ọrụ ọsọ kacha erughị decibel 50.

Safety
● Emepụtara dịka iwu nchekwa mba ụwa siri dị (dịka IEC 61010)
● Nchekwa mkpuchi mkpuchi eletrik, ọnụ ụzọ enweghị ike imeghe mgbe rotor na-agba ọsọ na igwe agaghị agba ọsọ mgbe mkpuchi meghere na koodu njehie pụtara.
● Mwepu mkpuchi mkpuchi mberede mgbe ike dara.
● Mkpịsị ọkụ gas maka nchekwa mkpuchi mkpuchi.
● A na-eme nchekwa nchekwa maka oke ọsọ, n'elu ikpo ọkụ (moto, ụlọ), enweghị aha, wdg iji hụ na nchekwa igwe mmadụ.

| Oke ọsọ (rpm) | 6000r / min | Izi ezi ọsọ | ± 10r / nkeji |
| Oke RCF (xg) | 4860gg | Oke ike(ml) | 4 × 100ml |
| Oge oge | 0~99mins | Noise (dBA) | 50DB |
| Ọnọdụ nchịkwa okpomọkụ | -9 ~ ~ + 40 ℃ | Okpomoku na-achịkwa ziri ezi | ℃ 1 ℃ |
| Net arọ (na-enweghị rotor) | 42kg | LCD | Metụ ihuenyo nnukwu agba inch ise |
| ike ọkọnọ | AC220V 50hz 10A, 500W | Dimension (mm) | 640 × 340 × 370mm (L × W × H) |
| Ee e | Rotor | Max ikike | Max. speed | Oke. RCF | Note |
NO.1![]() | rotor akụkụ | 24 × 5/10/15 ml | 6000r / min | 4860gg | PP / PC / nucleic acid tube |
| nkwụnye | 24 × 2ml | ||||
NO.2![]() | Ịwụ ịwụ | 4 × 100ml | 5000r / min | 3437gg | Iko iko |
| nkwụnye | 4 × 5 × 5ml | ||||
| nkwụnye | 4 × 4 × 10/8 ml | ||||
![]() | |||||
1. Onye na-emepụta centrifuge ọkachamara, ọnụahịa asọmpi.
2. ISO9001, ISO13485, CE, SFDA Asambodo, igwe niile na-enweta ule siri ike na nkwakọ ngwaahịa dị mma tupu ụgbọ njem.
3. Ogologo oge oru nkwado na ọkachamara ahịa ọrụ na ọ bụla ogbo nke ngwaahịa ahịa, nnyefe na operation.Our ukwuu ruru eru na ahụmahụ ọrụ otu na-enye gị na a pụrụ iche larịị nke nkwado gị zuo n'ihi na ọ bụ dum ndụ.
4. Anyị nwekwara ike na-enye ngwọta ahaziri maka ndị ahịa 'chọrọ pụrụ iche.
5. Kwadoro ya na otu ndị injinia na-arụ ọrụ nke ọma na-akwado site na afọ nke ahụmahụ na mpaghara ha, ụlọ ọrụ ahụ na-ahụ na ngwaahịa ọ bụla nke na-ahapụ ụlọ ọrụ mmepụta ihe ruru akara n'akụkụ niile.