All Categories
Gel Kaadị Centrifuge

Gel Kaadị Centrifuge

Ụlọ> ngwaahịa > Centrifuges > Clinical Centrifuge > Gel Kaadị Centrifuge

Otu ọbara Gel Kaadị Centrifuge Maka 4X12 Kaadị Nsonaazụ Ule Ọbara

ngwa:The Centrifuge MK-24  is used for processing the blood type cards.
Max. Kwuru ọsọ4000 rpm
Oke.RCF2978gg
Max ikike4 × 500ml
Rotors dakọtara12 kaadị / igbe maka ịwụ swing
DisplayLCD
Model Number:MK-24
asambodo:CE, ISO13485, ISO9001:2015
Akwụkwọ ikikeAkwụkwọ ikike afọ 1 maka igwe dum, akwụkwọ ikike afọ 3 maka compressor na akwụkwọ ikike afọ 5 maka moto. Akụkụ ngbanwe efu na mbupu n'ime akwụkwọ ikike.
  • Description
  • Nka na ụzụ nkọwa
  • Rotors na Ngwa
  • asọmpi Advantage

The Centrifuge MK-24 is of floor standing type,which can accommodate 4×12 blood type cards one time.

Design

● Ọdịdị nchara dị elu nke nwere ụlọ nchara na-agbawa agbawa, 304 # igwe anaghị agba nchara bụ autoclave-enwe ike , ndị na-eguzogide ọgwụ na mmiri mmiri disinfection.

● Microprocessor njikwa, mgbanwe aro mbanye usoro na-ebugharị ozugbo na-atụgharị isi, ezigbo na-agba ọsọ, obere ịma jijiji, obere mkpọtụ.

● Mbanye moto ntụgharị ugboro ugboro, njikwa microcomputer, agba mmetụ ihuenyo buru ibu.

● Mpempe ihe nlele na mkpuchi maka nhazi ọsọ ọsọ na nha mkpọtụ.

● Ihuenyo mmetụ 7-inch na-egosipụta paramita nke Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.

● Ihe mkpuchi ọnụ ụzọ na ahụ nwere mgbanaka akara silicone okpukpu abụọ.

FBTC4 Centrifuge

Dị mfe ojiji

● Enwere ike ịhazi ma chekwaa, na-echekwa ihe ruru mmemme 30 ma na-enye ndị ọrụ ohere ịnweta otu igodo igodo ozugbo. Oke echekwara: ngwakọta na-anọgide na ebe nchekwa ọbụlagodi mgbe agbanyụrụ centrifugation.

● Na-enye 10-speed acceleration na deceleration curves, iji zere nke ọma sedimentation nke abụọ, na mma centrifugation mmetụta.

● Mkpuchi mkpuchi akpaaka na ijide n'oge rotor na-agba ọsọ.

● Usoro nyocha nke onwe ya na ime ụlọ dị elu - mkpuchi na nchebe.

● Teknụzụ nwere ikike “ogbi”, ọkwa ụda erughị decibel 58 na arụ ọrụ ọsọ kacha elu.

● Ntụgharị rpm/rcf akpaaka

FBTC4 Centrifuge

Safety

● Emepụtara dịka iwu nchekwa mba ụwa siri dị (dịka IEC 61010)

● Nchekwa mkpuchi mkpuchi eletrik, ọnụ ụzọ enweghị ike imeghe mgbe rotor na-agba ọsọ na igwe agaghị agba ọsọ mgbe mkpuchi meghere na koodu njehie pụtara.

● Mwepu mkpuchi mkpuchi mberede mgbe ike dara (ọ bara ezigbo uru na nkwụsị ọkụ a na-atụghị anya ya).

● Mkpịsị ọkụ gas maka nchekwa mkpuchi mkpuchi.

● A na-eme nchekwa nchekwa maka oke ọsọ, n'elu ikpo ọkụ (moto, ụlọ), enweghị aha, wdg iji hụ na nchekwa igwe mmadụ.

FBTC4 Centrifuge
Oke ọsọ (rpm)0-4000rpm nwere ike idoziNoise (dBA)≦58dB(A)
Oke ike(ml)4 * 500 mlDimension (mm)775*620*900mm(LxWxH)
Oke RCF (xg)0-2978xg mgbanwenha ịbụ135 KG
ike ọkọnọAC220V,50HZ,10A,1200W
Ee eRotorikikeMax. speedOke.RCFNote

NO.1

2

Swing rotor4 × 12 kaadị4000r / min2978gg12 kaadị / igbe maka ịwụ swing

1.Professional centrifuge emeputa, ọnụahịa asọmpi.

2.ISO9001: 2015 Asambodo, Asambodo CE, igwe niile na-anwale ule dị mma na nkwakọ ngwaahịa dị mma tupu ụgbọ njem.

3.Long-okwu oru nkwado na ọkachamara ahịa ọrụ na ọ bụla ogbo nke ngwaahịa ahịa, nnyefe na operation.Our ukwuu ruru eru na ahụmahụ ọrụ otu na-enye gị na a pụrụ iche larịị nke nkwado maka gị zuo n'ihi na ọ bụ dum ndụ.

4.We nwekwara ike na-enye ngwọta ahaziri maka ndị ahịa 'chọrọ pụrụ iche.

5.Powered na otu ndị na-arụ ọrụ nke ọma nke ndị injinia na-akwado site na afọ nke ahụmahụ na mpaghara ha, ụlọ ọrụ ahụ na-eme ka ngwaahịa ọ bụla na-ahapụ ụlọ ọrụ mmepụta ihe ruru akara n'akụkụ niile.

NCHỌPỤTA
0
Nkata nyocha
    Ajuju ase gi bu ihe efu
Efuase