ỌH HR H HOT
Igwe Centrifuge Refrigerated dị elu nke ukwuu 21000 Rpm Benchtop Lab Centrifuge
| ngwa: | Ụlọ ọgwụ, ụlọ ọgwụ anụmanụ, ụlọ nyocha nri, mahadum & kọleji, ụlọ nyocha ọgwụ, ụlọ nyocha omenala cell |
| Max. Kwuru ọsọ | 21000rpm nwere rotor n'akụkụ kwụ ọtọ 12x1.5/2.2ml |
| Oke.RCF | 31061gg |
| Max ikike | 4 * 100ml rotor akụkụ kwụ ọtọ |
| Ọnọdụ nchịkwa okpomọkụ | -20 ~ ~ + 40 ℃ |
| Rotors dakọtara | Rotors akụkụ a kapịrị ọnụ |
| Display | LCD |
| Model Number: | TGL-20M |
| asambodo: | CE, ISO13485, ISO9001, SFDA |
| Akwụkwọ ikike | Akwụkwọ ikike afọ 1 maka igwe dum, akwụkwọ ikike afọ 3 maka compressor na akwụkwọ ikike afọ 5 maka moto. Akụkụ ngbanwe efu na mbupu n'ime akwụkwọ ikike. |
- Description
- Video
- Nka na ụzụ nkọwa
- Rotors na Ngwa
- asọmpi Advantage
Benchtop dị elu refrigerated centrifuge TGL-20M nwere ike iru oke ọsọ nke 21000rpm, ọ nwere ike dabara na rotors isi n'akuku maka mpịakọta agbanwe, ikike kachasị bụ 4 * 100ml.
Njirimara refrigeration na-enye ohere maka njikwa okpomọkụ n'oge usoro nkewa, nke dị mkpa maka ịnọgide na-eguzosi ike n'ezi ihe nke ụfọdụ ihe atụ. Emebere ya ka ọ nabata ụdị rotors na ihe nkwụnye dị iche iche, na-eme ka ọ dị mma maka centrifugation dị elu nke mpịakọta sitere na 0.2ml ruo 100ml. Nhazi kọmpat ya na-eme ka ọ dị mma maka ụlọ nyocha nwere oke ohere.
Design
● Ụlọ ígwè, mkpuchi ígwè, na igwe anaghị agba nchara centrifuge ụlọ bụ autoclave nwere ike na-eguzogide ọgwụ na mmiri mmiri na-efe efe.
● Mpempe ihe nlele na mkpuchi maka nhazi ọsọ ọsọ na nha mkpọtụ.
● Microprocessor njikwa na ugboro mgbanwe AC moto mbanye
● LCD Gosipụta paramita nke Ọsọ, Ngụ oge, RCF, Rotors, Mmemme (Ncheta), Acceleration& Deceleration ozi na ozi koodu njehie.
● mgbanaka akara okpukpu abụọ emere maka mkpuchi centrifuge na ngwa iji chekwaa ogologo akara nke ọma.

Dị mfe ojiji
● Igwe nju oyi na-enweghị CFC, ihe mmetụta okpomọkụ dị n'ime ụlọ, njirimara tupu oyi, njikwa okpomọkụ ziri ezi ruo -20C.
● Enwere ike ịhazi ma chekwaa, na-echekwa ihe ruru mmemme 30 ma na-enye ndị ọrụ ohere ịnweta otu igodo igodo ozugbo. Oke echekwara: ngwakọta na-anọgide na ebe nchekwa ọbụlagodi mgbe agbanyụrụ centrifugation.
● Na-enye 10 osooso ọnụego na 10 braking ramp, iji zere nke ọma sedimentation nke abụọ, na mma centrifugation mmetụta.
● Mkpuchi mkpuchi akpaaka na ijide n'oge rotor na-agba ọsọ
● rotors na-agbanwe ngwa ngwa, njikọ rotor pụrụ iche nke na-eme ka ọ dị mfe ibu na ibutu rotor.
● Nchọpụta nsogbu akpaaka na-egosi koodu njehie na mkpu na ihuenyo.
● Ọkwa mkpọtụ dị ala karịa decibel 58 n'ọsọ ntụgharị kachasị elu.
● Sistemụ njirimara rotor akpaaka, njirimara rotor koodu na-egbochi rotor ịfefe oke.

Safety
● Asambodo nchekwa na ụkpụrụ: CE
● Nchekwa ngwaahịa: EN61010-1 na EN 61010-2-020,
● Ndakọrịta elektrọnik: EN 61326-1
● Nchekwa mkpuchi mkpuchi eletrik, ọnụ ụzọ enweghị ike imeghe mgbe rotor na-agba ọsọ na igwe agaghị agba ọsọ mgbe mkpuchi meghere na koodu njehie pụtara.
● Mwepu mkpuchi mkpuchi mberede mgbe ike dara (ọ bara ezigbo uru na nkwụsị ọkụ a na-atụghị anya ya).
● Mkpịsị ọkụ gas maka nchekwa mkpuchi mkpuchi.
● A na-eme nchekwa nchekwa maka oke ọsọ, n'elu ikpo ọkụ (moto, ụlọ), enweghị aha, wdg iji hụ na nchekwa igwe mmadụ.

| Oke ọsọ (rpm) | 0-21000rpm nwere ike idozi | Oge oge | 1-99 nkeji mgbanwe |
| Oke ike(ml) | 4 * 100ml | Izi ezi ọsọ | ± 10r / nkeji |
| Oke RCF (xg) | 0-31061xg mgbanwe | ACC/DEC | 1-10 ọnụego |
| Ọnọdụ nchịkwa okpomọkụ | -20 ~ ~ + 40 ℃ | Okpomoku na-achịkwa ziri ezi | ℃ 1 ℃ |
| Noise (dBA) | 于58dB(A) | Net arọ (na-enweghị rotor) | 80KGS |
| ike ọkọnọ | AC220V, 50HZ, 10A, 880W | Dimension (mm) | 600x570x380mm(LxWxH) |
| Ee e | item | Max. ikike | Max. Kwuru | Oke.RCF | Note |
NO.1
|
rotor akụkụ | 12 × 1.5 / 2.2ml | 21000r / min | 31061gg | PP / PC tube |
| nkwụnye | 12 × 0.5ml | PP / PC tube | |||
| nkwụnye | 12 × 0.2ml | PP / PC tube | |||
NO.2
|
rotor akụkụ | 12 × 5ml | 16500r / min | 19480gg | PP / PC tube |
| nkwụnye | 12 × 1.5ml | PP / PC tube | |||
NO.3
|
rotor akụkụ | 12 × 10ml | 15000r / min | 21130gg | PP / PC tube |
| nkwụnye | 12 × 5ml | PP / PC tube | |||
| nkwụnye | 12 × 1.5ml | PP / PC tube | |||
NO.4
|
rotor akụkụ | 24 × 1.5 / 2.2ml | 16000r / min | 24843gg | PP / PC tube |
| nkwụnye | 24 × 0.5ml | PP / PC tube | |||
| nkwụnye | 24 × 0.2ml | PP / PC tube | |||
N0.5
|
rotor akụkụ | 48 × 1.5 / 2.2ml | 14000r / min | 20379gg | PP / PC tube |
| nkwụnye | 48 × 0.5ml | PP / PC tube | |||
| nkwụnye | 48 × 0.2ml | PP / PC tube | |||
NO.6
|
rotor akụkụ | 12 × 8 × 0.2ml | 12000r / min | 16985gg | PCR 8-tube ibe |
NO.7
|
rotor akụkụ | 10 × 15ml | 13000r / min | 19650gg | PP / PC tube |
| nkwụnye | 10 × 5ml | PP / PC tube | |||
| nkwụnye | 10 × 1.5ml | PP / PC tube | |||
NO.8
|
rotor akụkụ | 6 × 50ml | 13000r / min | 18327gg | PP / PC tube |
| nkwụnye | 6 × 15ml | PP / PC tube | |||
| nkwụnye | 6 × 10ml | PP / PC tube | |||
| nkwụnye | 6 × 5ml | PP / PC tube | |||
| nkwụnye | 6 × 1.5ml | PP / PC tube | |||
NO.9
|
rotor akụkụ | 4 × 100ml | 11000r / min | 13284gg | PP / PC tube |
| nkwụnye | 4 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 15ml | PP / PC tube | |||
| nkwụnye | 4 × 10ml | PP / PC tube | |||
| nkwụnye | 4 × 5ml | PP / PC tube | |||
| nkwụnye | 4 × 1.5ml | PP / PC tube | |||
![]() | |||||
1.Professional centrifuge emeputa, ọnụahịa asọmpi.
2.ISO9001, ISO13485, CE, SFDA Asambodo, igwe niile na-enweta ule siri ike na nkwakọ ngwaahịa dị mma tupu ụgbọ njem.
3.Long-okwu oru nkwado na ọkachamara ahịa ọrụ na ọ bụla ogbo nke ngwaahịa ahịa, nnyefe na operation.Our ukwuu ruru eru na ahụmahụ ọrụ otu na-enye gị na a pụrụ iche larịị nke nkwado maka gị zuo n'ihi na ọ bụ dum ndụ.
4.We nwekwara ike na-enye ngwọta ahaziri maka ndị ahịa 'chọrọ pụrụ iche.
5.Powered na otu ndị na-arụ ọrụ nke ọma nke ndị injinia na-akwado site na afọ nke ahụmahụ na mpaghara ha, ụlọ ọrụ ahụ na-eme ka ngwaahịa ọ bụla na-ahapụ ụlọ ọrụ mmepụta ihe ruru akara n'akụkụ niile.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ


















