ỌH HR H HOT
Nnukwu ikike Centrifuge nwere UV Lamp Biosafety maka ụlọ nyocha na ahụike
| ngwa: | Ụlọ nyocha ụlọ ọrụ, ụlọ ọgwụ, ụlọ ọgwụ anụmanụ, ụlọ nyocha nri, mahadum & kọleji, ụlọ nyocha ọgwụ, ụlọ nyocha ọdịnala cell |
| Max. Kwuru ọsọ | 6000 rpm |
| Oke.RCF | 4752gg |
| Max ikike | 4 * 1000ml |
| Rotors dakọtara | Rotor akụkụ kwụ ọtọ, bọket swing |
| Display | LCD |
| Model Number: | DL-5M |
| asambodo: | CE, ISO13485, ISO9001, SFDA |
| Akwụkwọ ikike | Akwụkwọ ikike afọ 1 maka igwe dum, akwụkwọ ikike afọ 3 maka compressor na akwụkwọ ikike afọ 5 maka moto. Akụkụ ngbanwe efu na mbupu n'ime akwụkwọ ikike. |
- Description
- Video
- Nka na ụzụ nkọwa
- Rotors na Ngwa
- asọmpi Advantage
DL-5M centrifuge nke nwere friji nke nwere ike ịhazi rotor nwere ikike dị ukwuu dịka 4 * 1000ml ma nwee ike ịhazi rotor swing out, nke a na-ejikarị eme ihe n'ọhịa nke ebe a na-enye ọbara, ụlọ ọrụ ọgwụ, biochemistry, ngwaahịa bayoloji, wdg. Ọ bụ ngwaọrụ kacha mma maka nkewa ọbara, mmiri ozuzo protein na nchịkọta mkpụrụ ndụ ma kwekọọ na asambodo nchekwa CE, asambodo mma ISO9001 na 13485.
Design
● Ụlọ ígwè, mkpuchi ígwè, na igwe anaghị agba nchara centrifuge ụlọ bụ autoclave nwere ike na-eguzogide ọgwụ na mmiri mmiri na-efe efe.
● Mpempe ihe nlele na mkpuchi maka nhazi ọsọ ọsọ na nha mkpọtụ.
● Microprocessor njikwa na ugboro mgbanwe AC moto mbanye
● LCD Gosipụta paramita nke Ọsọ, Ngụ oge, RCF, Rotors, Mmemme (Ncheta), Acceleration& Deceleration ozi na ozi koodu njehie.
● mgbanaka akara okpukpu abụọ emere maka mkpuchi centrifuge na ngwa iji chekwaa ogologo akara nke ọma.
● Bio-safety: gas na-atụgharị isi na-agbanwe agbanwe nke nwere ike igba ogwu na okpomọkụ dị elu, oghere centrigual na ọrụ sterilization ultraviolet, banye na steeti sterilization mgbe ịgbanye igwe ahụ.
● Multi-layers imewe maka nkwụnye ọkụ, na-arụ ọrụ maka 100mm na 75mm tube, wepụ mkpuchi na-akpaghị aka, melite arụmọrụ.
● Nchekwa bio: isi na-agbagharị agbagharị gas nke nwere ike igba ogwu na oke okpomọkụ, oghere centrifugal na ọrụ sterilization ultraviolet, banye na steeti sterilization mgbe ịgbanyechara ya.

Dị mfe ojiji
● Enwere ike ịhazi ma chekwaa, na-echekwa ihe ruru mmemme 30 ma na-enye ndị ọrụ ohere ịnweta otu igodo igodo ozugbo. Oke echekwara: ngwakọta na-anọgide na ebe nchekwa ọbụlagodi mgbe agbanyụrụ centrifugation.
● Na-enye 10 osooso ọnụego na 10 braking ramp, iji zere nke ọma sedimentation nke abụọ, na mma centrifugation mmetụta.
● Mkpuchi mkpuchi akpaaka na ijide n'oge rotor na-agba ọsọ
● rotors na-agbanwe ngwa ngwa, njikọ rotor pụrụ iche nke na-eme ka ọ dị mfe ibu na ibutu rotor.
● Nchọpụta nsogbu akpaaka na-egosi koodu njehie na mkpu na ihuenyo.
● Teknụzụ patent “Ogbi.” Ọkwa mkpọtụ dị ala karịa decibel 55 n'ọsọ ntụgharị kachasị elu.
● Ntụgharị rpm/rcf akpaaka
● Sistemụ njirimara rotor akpaaka, njirimara rotor koodu na-egbochi rotor ịfefe oke.
● Sistemụ refrigeration n'efu nke CFC, njirimara tupu emeju oyi, njikwa okpomọkụ nke ọma ruo - 20°C.

Safety
● Emepụtara dịka iwu nchekwa mba ụwa siri dị (dịka IEC 61010)
● Nchekwa mkpuchi mkpuchi eletrik, ọnụ ụzọ enweghị ike imeghe mgbe rotor na-agba ọsọ na igwe agaghị agba ọsọ mgbe mkpuchi meghere na koodu njehie pụtara.
● Mwepu mkpuchi mkpuchi mberede mgbe ike dara (ọ bara ezigbo uru na nkwụsị ọkụ a na-atụghị anya ya).
● Mkpịsị ọkụ gas maka nchekwa mkpuchi mkpuchi.
● A na-eme nchekwa nchekwa maka oke ọsọ, n'elu ikpo ọkụ (moto, ụlọ), enweghị aha, wdg iji hụ na nchekwa igwe mmadụ.

| Oke ọsọ (rpm) | 0-6000rpm nwere ike idozi | Oge oge | 1-99 nkeji mgbanwe |
| Oke ike(ml) | 4 * 1000ml | Izi ezi ọsọ | ± 10r / nkeji |
| Oke RCF (xg) | 0-4752xg mgbanwe | ACC/DEC | 1-10 ọnụego |
| Ọnọdụ nchịkwa okpomọkụ | -20 ~ ~ + 40 ℃ | Okpomoku na-achịkwa ziri ezi | ℃ 1 ℃ |
| Noise (dBA) | 58dB (A) | Net arọ (na-enweghị rotor) | 200KGS |
| ike ọkọnọ | AC220V, 50HZ, 10A, 1800W | Dimension (mm) | 790x670x900mm(LxWxH) |
| Ee e | item | Max. ikike | Max. Kwuru | Oke.RCF | Note |
|
NO.1
|
rotor akụkụ | 12 x 15/10/5ml | 6000r / min | 4588gg | PP / PC tube |
| nkwụnye | 12 x 2 ml | PP / PC tube | |||
|
NO.2 |
Swing rotor | Igwe igwe rotor | 5000r / min | 4752gg | PP / PC tube |
| Igwe ọkụ ọkụ | 4 x 100 ml | PP / PC tube | |||
| Igwe ọkụ ọkụ | 4 x 50 ml | PP / PC tube | |||
| nkwụnye | 4 x 10 / 15 ml | PP / PC tube | |||
|
N0.3 |
Swing rotor | Igwe igwe rotor | 4000r / min | 3041gg | PP / PC tube |
| Igwe ọkụ ọkụ | 4 × 2 × 100ml | PP / PC tube | |||
| Igwe ọkụ ọkụ | 4 × 2 × 50ml | PP / PC tube | |||
| Igwe ọkụ ọkụ | 4×8×15/10/5ml | PP / PC tube | |||
| nkwụnye | 4 × 2 × 10/15 ml | PP / PC tube | |||
| Ebu | 4 × 12 × 5/2 ml | PP / PC tube | |||
|
NO.4 |
Ịwụ ịwụ | 4 × 18×5/2ml | 4000r / min | 2773gg | Ịhapụ tubes mkpokọta ọbara |
|
NO.5 |
Ịwụ ịwụ | 4 × 600ml | 4000r / min | 3354gg | Iko nkwudo akụkụ anọ |
| Na-ewepụ ihe nkwụnye ọkụ | 4 × 25 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 4 × 12 × 15/10 ml | PP / PC tube | |||
| nkwụnye | 4 × 5 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 4 × 100ml | PP / PC tube | |||
|
NO.6 |
Ịwụ ịwụ | 6 × 600ml | 4000r / min | 3400gg | Iko nkwudo akụkụ anọ na mkpuchi ifufe |
| Na-ewepụ ihe nkwụnye ọkụ | 6 × 25 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 6 × 12 × 15/10 ml | PP / PC tube | |||
| nkwụnye | 6 × 5 × 50ml | PP / PC tube | |||
| nkwụnye | 6 × 4 × 100ml | PP / PC tube | |||
| NO.7 | Ịwụ ịwụ | 4 × 500ml | 4000r / min | 3354gg | Gburugburu na-eche Iko |
| nkwụnye | 4 × 17 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 4 × 8 × 15/10 ml |
PP / PC tube |
|||
| nkwụnye | 4 × 3 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 100ml | PP / PC tube | |||
| NO.8 | Ịwụ ịwụ | 6 × 500ml | 4000r / min | 3400gg | Gburugburu na-eche iko nwere mkpuchi ifufe |
| nkwụnye | 6 × 17 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 6 × 8 × 15/10 ml |
PP / PC tube |
|||
| nkwụnye | 6 × 3 × 50ml | PP / PC tube | |||
| nkwụnye | 6 × 100ml | PP / PC tube | |||
| NO.9 | Ịwụ ịwụ | 4 × 800ml | 4000r / min | 3443gg | Iko nkwudo akụkụ anọ nwere mkpuchi ifufe |
| Na-ewepụ ihe nkwụnye ọkụ | 4 × 30 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 4 × 12 × 15/10 ml |
PP / PC tube |
|||
| nkwụnye | 4 × 6 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 4×100ml | PP / PC tube | |||
| NO.10 | Ịwụ ịwụ | 4 × 750ml | 4000r / min | 3443gg | Iko nkwudo gburugburu |
| nkwụnye | 4 × 26 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 4 × 13 × 15/10 ml |
PP / PC tube |
|||
| nkwụnye | 4 × 5 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 3×100ml | PP / PC tube | |||
| NO.11 | Ịwụ ịwụ | 4 × 1000ml | 4000r / min | 3578gg | Iko kwụgidere Rhomboid nwere mkpuchi ifufe |
| Na-ewepụ ihe nkwụnye ọkụ | 4 × 42 × 5/2 ml | PP / PC tube | |||
| nkwụnye | 4 × 18 × 15/10 ml |
PP / PC tube |
|||
| nkwụnye | 4 × 7 × 50ml | PP / PC tube | |||
| nkwụnye | 4 × 4×100ml | PP / PC tube | |||
| NO.12 | Microplate rotor | 4 × 2 × 96 oghere | 4200r / min | 3284gg | 4 × 2 × 96 efere oghere miri emi 4×4×96 efere oghere dị omimi |
| nkwụnye | 4 × 32×1.5ml | ||||
![]() | |||||
1.Professional centrifuge emeputa, ọnụahịa asọmpi.
2.ISO9001, ISO13485, CE, SFDA Asambodo, igwe niile na-enweta ule siri ike na nkwakọ ngwaahịa dị mma tupu ụgbọ njem.
3.Long-okwu oru nkwado na ọkachamara ahịa ọrụ na ọ bụla ogbo nke ngwaahịa ahịa, nnyefe na operation.Our ukwuu ruru eru na ahụmahụ ọrụ otu na-enye gị na a pụrụ iche larịị nke nkwado maka gị zuo n'ihi na ọ bụ dum ndụ.
4.We nwekwara ike na-enye ngwọta ahaziri maka ndị ahịa 'chọrọ pụrụ iche.
5.Powered na otu ndị na-arụ ọrụ nke ọma nke ndị injinia na-akwado site na afọ nke ahụmahụ na mpaghara ha, ụlọ ọrụ ahụ na-eme ka ngwaahịa ọ bụla na-ahapụ ụlọ ọrụ mmepụta ihe ruru akara n'akụkụ niile.