ỌH HR H HOT
Standard Central Ultrapure Water System maka Oral Cavity & Gastroenteroscopy Jiri
- Description
- Nka na ụzụ nkọwa
Njirimara sistemu>>
● Ogo mmiri nke mmiri a na-emepụta na-akwado "WS 507-2016" nkọwapụta teknụzụ maka nhicha na disinfection nke endoscopes dị nro na "GB5749-2006" ọkọlọtọ mmiri dị ọcha.
● Arụ ọrụ akpaaka, nchebe megide nrụgide dị ala na ụkọ mmiri nke mmiri mmiri, nkwụsịtụ akpaaka mgbe oke nrụgide / jupụtara na mmiri, nleba anya n'ezie nke isi conductivity LCD mmiri mmiri kristal ngosi.
● Microcomputer akpaaka nwere ọgụgụ isi njikwa, njikwa bọtịnụ mmetụ aka, nleba anya nleba anya n'otu oge nke ọnọdụ ọrụ ọ bụla, ihe ngosi na-egbukepụ egbukepụ na ụda olu na-arụ ọrụ.
● Shei nke ihe eji eme ihe na-anabata ụdị ngwa ngwa ngwa ngwa modular, nke dị mfe ma dị ngwa iji dochie ya.
● Usoro usoro ihe omume na-achịkwa ịkwanye akpaka, na-agbanye akpaka mgbe igwe na-agbanye na mgbe mmiri jupụtara, na-agbatị ndụ ọrụ nke RO.
● A na-eji ígwè sterilizer ultraviolet na ozone generator mee ihe iji chịkwaa uto nke nje bacteria, a pụkwara ịgbakwụnye ihe na-emepụta ozone ma ọ bụrụ na e nwere pipeline.
● Microfilter na njedebe nke usoro ahụ na nhazi ọma jikọtara ya na-eme ka mmiri dịkwuo mma ma bụrụ nke a pụrụ ịdabere na ya, na ntinye nkwụnye nke ngwa ahụ na-eme ka ọ dịkwuo mfe iji dochie ngwa.
● Usoro ahụ nwere ike ịrụ ọrụ dị ala, obere mkpọtụ, yana ike mgbochi nnyonye anya siri ike. Enwere ike ịhọrọ ngwa dị iche iche maka àgwà mmiri dị mgbagwoju anya.
● Mgbe turbidity nke mgbata mmiri dị elu, a na-atụ aro ka ịtinye ngwaọrụ nzacha tupu akpaaka, nke nwere ike ịrụ ọrụ nke ọma na-adịghị mma. (nhọrọ)
● Ngwa ngwa: oghere ọnụ ụlọ ọgwụ, oche eze na ụlọ ọrụ ndị ọzọ na-akwado, gastroenteroscopy center maka nhicha na disinfection nke ngwá ọrụ ahụike, arịa na ihe, wdg.
Mmiri dị mma ga-emetụta àgwà nke mmiri dị ọcha na ndụ nke kọlụm nzacha, mgbe TDS na-emetụta ≥ 20 0 ppm , a na-atụ aro ka ịgbakwunye ngwaọrụ na-eme ka ọ dị nro ma ọ bụ jiri usoro osmosis nke okpukpu abụọ.
Tupu nhazi; Ngwakọta PP owu (PP); Carbon arụnyere arụ ọrụ (DUF); ntụgharị osmosis (RO); mgbanwe ion (DI); UV ìhè igba ogwu (UV); Ozone disinfection (CY); ultrafiltration (UF); nzacha ọnụ (TF)
Nka na ụzụ kwa:
| ụdị Nọmba | MK-XD100L/MK-XD200L/MK-300L |
| usoro eruba | 100/150LPP+DUF+RO+UV 200L/300LPP+DUF+RO+UV+(CY) |
| Mmepụta mmiri | 100/150/200/300L |
| Ogo mmiri ngwaahịa | arụmọrụ≤10 anyị / cm, Ọnụ ọgụgụ nje bacteria <10 cfu / ml, Ọnụego mwepụ nke nje bacteria ≥99.9% |
System chọrọ
| ịnye ọkụ | 220V/AC 200W 50Hz100/200L-200W, 200L/1-2KW, 300L/2-3KW |
| Mmiri chọrọ | Obodo mgbata mmiri tdS≤200ppm |
| Ntinye mmiri | 0.2-0.4Mpa |
| okpomọkụ Emefu | 5-45 ℃ |
| Ebe echichi | Igwe ikuku, ihe na-egbochi mmiri, mgbochi corrosion |
| Enwere ike ịhazi mmepụta mmiri kwekọrọ dịka mkpa dị n'ezie | |